USX

Features

  • 9 to 64 W/m @ 10°C
  • Tmax maintain 240°C
  • 110-120 or 208-277 Vac
Request a quote Give us a call or send an email phonelink_ring +31 (0)183-201088 forward_to_inbox sales@tc-e.nl

Application

Thermon USX self-regulating heat tracing cables are specifically engineered for critical process maintenance for temperatures up to 240°C and freeze protection applications where ultra high temperature ratings are required. USX enables the use of ambient sensing controls for applications with continuous exposure temperatures up to 240°C. Constructed using Thermon’s unique and proven monolithic co-extrusion process, USX advances self-regulating heat tracing technology to the ultimate frontiers of performance and reliability

The heat output of the USX cables varies in response to the surrounding conditions along the entire length of a circuit. Whenever the heat loss of the insulated pipe, tank or equipment increases (as ambient temperature drops), the heat output of the cable increases. Conversely, when the heat loss decreases (as the ambient temperature rises or product flows), the cable reacts by reducing its heat output. USX heat tracing cables are available with a fluoropolymer (FOJ) overjacket for higher chemical resistance against aggressive organics and corrosives.

The USX heat trace cables are approved for use in ordinary (nonclassified) areas and hazardous (classified) areas.

Features

  • Pipe freeze protection and temperature maintenance up to 240°C
  • Safe and efficient in operation, uniform pipe temperatures and energy saving technology
  • Semiconductive self-regulating heating matrix allows for overlaps without overheating
  • Withstands temperatures associated with steam purging
  • Cut-to-length parallel circuitry
  • Nickel-plated copper bus wires
  • Metallic braid for grounding purposes
  • Available voltages 110-120 or 208-277 Vac
  • Unique monolithic co-extrusion processing for optimal performance
  • Compatible with user-friendly and easy to install Thermon components
USX product variants
SKU P/N Item Power output @ 10°C Voltage (Vac) Overjacket
TMN.A01.048 26812 USX 3-2 OJ 9 W/m, 230 Vac 208-277 Fluoropolymer
TMN.A01.042 26802 USX 3-1-OJ 10 W/m, 120 Vac 110-120 Fluoropolymer
TMN.A01.049 26832 USX 6-2-OJ 19 W/m, 230 Vac 208-277 Fluoropolymer
TMN.A01.043 26822 USX 6-1-OJ 20 W/m, 120 Vac 110-120 Fluoropolymer
TMN.A01.050 26852 USX 9-2-OJ 29 W/m, 230 Vac 208-277 Fluoropolymer
TMN.A01.044 26842 USX 9-1-OJ 30 W/m, 120 Vac 110-120 Fluoropolymer
TMN.A01.051 26872 USX 12-2-OJ 38 W/m, 230 Vac 208-277 Fluoropolymer
TMN.A01.045 26862 USX 12-1-OJ 39 W/m, 120 Vac 110-120 Fluoropolymer
TMN.A01.052 26952 USX 15-2-OJ 49 W/m, 230 Vac 208-277 Fluoropolymer
TMN.A01.046 26942 USX 15-1-OJ 49 W/m, 120 Vac 110-120 Fluoropolymer
TMN.A01.053 26972 USX 20-2-OJ 64 W/m, 230 Vac 208-277 Fluoropolymer
TMN.A01.047 26962 USX 20-1-OJ 66 W/m, 120 Vac 110-120 Fluoropolymer

Certifications/Approvals

CE
0344

Ex
Ex 60079-30-1 IIC T* Gb
Ex 60079-30-1 IIIC T** Db

*T3 for EPL Gb; T200°C for EPL Db for USX 3-2, 6-2, 9-2, 12-2, 15-2
** 230°C (T2) for EPL Gb; T230°C for EPL Db; for USX 20-2

IEC IECEx

CSANe 20ATEX3059
IECEx CSA 20.0006

Canadian Standards Association
Ordinary Locations
Hazardous (Classified) Locations

Canada:
Class I, Division 1, Groups A, B, C and D
Class II, Division 1, Groups E, F and G
Class III Ex 60079-30-1 IIC Gb Ex 60079-30-1 IIIC Db

US:
Class I, Division 2, Groups A, B, C and D
Class II, Division 2, Groups E, F and G
Class III
Class I Zone 1 AEx 60079-30-1 IIC Gb
Class II Zone 21 AEx 60079-30-1 IIIC Db

Specifications

General

Manufacturer
Thermon
Unit of measurement
Meter

Ratings

Available watt densities at 230 Vac
9, 19, 29, 38, 48, 64 W/m @ 10°C
Available watt densities at 120 Vac
10, 20, 30, 39, 49, 66 W/m @ 10°C
Supply voltage
110-120 or 208-277 Vac
Maximum continuous exposure temperature
Power-on 240°C
Minimum installation temperature
-60°C
Minimum bend radius (metric)
-15°C = 10 mm | -60°C = 32 mm