KSR

Features

  • 90 W/m @ 0°C
  • Surface snow melting
  • 208-277 Vac
Request a quote Give us a call or send an email phonelink_ring +31 (0)183-201088 forward_to_inbox sales@tc-e.nl

Application

Thermon KSR self-regulating heating trace heaters are an integral part of Thermon’s SnoTrace snow and ice melting systems. Designed and approved specifically for direct burial, KSR withstands the harsh conditions encountered during concrete placement.

The self-regulating heat output of KSR varies in response to the surrounding concrete temperatures. When the concrete is at or below freezing temperatures, KSR will deliver the maximum power output. As the concrete warms up, the power output will decrease. Energy efficiency can be accomplished without special or sophisticated controls.

EASY TO DESIGN
Determining the circuit layout of KSR for a snow and ice melting system is easy. The step-by-step design guide leads the reader through determining the heating requirements, selecting the trace heater spacing and establishing the number of heating circuits and accessories required to complete the SnoTrace system.

With cut-to-length parallel circuitry, KSR easily adapts to variations in design found at the job site. This can reduce or eliminate the need to redesign circuits off-site without details or sufficient time to react.

EASY TO INSTALL
The demanding environment associated with forms, reinforcing steel and concrete placement requires that the trace heater be rugged. The fluoropolymer jacketed KSR with an additional silicone rubber outer jacket provides the needed durability. Yet it is flexible enough to adapt to steps, curved walkways, landings or other confined areas.

Installing and terminating KSR is easy. Simply unreel the amount of trace heater needed for the area/circuit and terminate with Thermon circuit fabrication kits and accessories. Power connection, splice kits, end termination and expansion joint kits are all designed specifically for the demanding application.

Features

  • Semiconductive self-regulating heating matrix
  • Cut-to-length parallel circuitry
  • Nickel-plated copper bus wires
  • Metallic braid for grounding purposes
  • Flexible and simple to design for stairs and complex layouts
  • Durable construction design for long-term operation
KSR product variants
SKU P/N Item Power output @ 0°C Voltage (Vac) Overjacket
TMN.A10.010 256011 KSR 2-OJ 90 W/m 208-277 Silicone rubber

Certifications/Approvals

CE Ex
II 2 G Ex eb IIC T3, II 2 D Ex tb IIIC T200°C UL xxATEXxxxx

IEC IECEx
IECEx UL xx.xxxx Ex eb IIC T3, Ex tb IIIC T200°C

UL Listed

Canadian Standards Association

Specifications

General

Manufacturer
Thermon
Unit of measurement
Meter

Ratings

Available watt densities
90 W/m @ 0°C
Supply voltages
208-277 Vac
Maximum continuous exposure temperature
Power-off 121°C
Minimum installation temperature
-60°C
Minimum bend radius
32 mm