Application
The Thermon Terminator ZS/ZE end terminations are designed to fabricate accessible outside-the-insulation splices or end terminations of Thermon heating cables. Electrical connections are made using wire fasteners. For applications requiring terminations to be made with terminal block connections, the Terminator ZP kits may be used.
Terminator ZS/ZE kits are approved for use in ordinary (nonclassified) areas, and are certified to the ATEX directive for use in Category 2 and 3 (Zone 1 and 2) classified areas.
SKU | P/N | Item | Cable profile | Mounting type | Market |
---|---|---|---|---|---|
TMN.A30.016 | 23491 | TERMINATOR ZS/ZE | BSX, RSX, KSX, HTSX, USX, VSX-HT, HPT, FP | Pipe | Europe |
Resources
Datasheet
English (Europe) datasheet
Sales brochure
English (Europe) sales brochure
Installation manual
English (Europe) installation instructions
Certifications/Approvals
CE
0344 2809
Ex
II 2 GD Ex db eb IIC T6...T5, Ex tb IIIC T85°C…T100°C
FM 10ATEX0058X
IEC IECEx
IECEx FMG 10.0022X Ex db eb IIC T6...T5
Ex tb IIIC T85°C…T100°C
Specifications
General
- Manufacturer
- Thermon
- Unit of measurement
- Piece
Ratings
- Enclosure Rating
- IP66
- Maximum pipe exposure temperature
- 250°C
- Minimum installation temperature
- -60°C
- Operating ambient temperature
- -60°C to +55°C
- Electrical connection
- Wire fasteners
- Number of power connections
- n/a
- Number of in-line/ T-splices
- 1 in-line
- Number of end terminations
- 1 to 2 cables
- Maximum conductor size
- n/a
- Maximum voltage rating
- 750 Vac
- Maximum rated current
- n/a
- T-rating, Ta = 40°C
- T4 @ 46 Amps / T6 @ 22 Amps