TubeTrace with VSX-HT

Features

  • 9, 15, 25 & 32 W/m @ 10°C
  • Tmax maintain 149°C
  • Cut-to-length
Request a quote Give us a call or send an email phonelink_ring +31 (0)183-201088 forward_to_inbox sales@tc-e.nl

Application

Thermon TubeTrace, with “cut-to-length” VSX-HT self-regulating heat tracing, is designed to provide freeze protection or temperature maintenance from 5°C (40°F) to 149°C (300°F) for tubing where high temperature exposure capability is possible. VSX-HT withstands intermittent temperature exposures of 232°C (450°F).

Thermon TubeTrace bundles with VSX-HT heat trace cables are approved for use in ordinary (nonclassified) areas and hazardous (classified) areas.

Features

  • Pipe freeze protection and temperature maintenance up to 149°C (300°F)
  • Power output of the VSX-HT cable varies in response to the surrounding conditions along the entire length of a circuit
  • Lower risk of overheating the tube or product
  • Installed cost is lower because “cut-to-length” VSX-HT cable makes end connections easy with minimal waste
  • VSX-HT cable is approved for use in ordinary (non-classified) areas and hazardous (classified) areas
  • Polymer outer jacket (ATP or TPU available)

Certifications/Approvals

FM Approvals
Ordinary Locations
Hazardous (Classified) Locations
Class I, Division 2, Groups B, C and D
Class II, Division 2, Groups F and G
Class III, Divisions 1 and 2
Class I, Zones 1 and 2, AEx eb IIC, AEx tb IIIC

Canadian Standards Association
Ordinary Locations
Hazardous (Classified) Locations
Class I, Division 1, Groups A, B, C and D
Class II, Division 1, Groups E, F and G
Class I, Division 2, Groups A, B, C and D
Class II, Division 2, Groups E, F and G
Ex eb IIC, Ex tb IIIC

Specifications

General

Manufacturer
Thermon
Unit of measurement
Meter

Ratings

Available watt densities (°C) 230 Vac
15, 32, 48, 64 W/m @ 10°C
Available watt densities (°C) 240 Vac
16, 33, 49, 66 W/m @ 10°C
Available watt densities (°F) 120 Vac
5, 10, 15, 20 W/ft @ 50°F
Supply voltages
110-120 or 208-277 Vac
Tube temperature range
5°C to 149°C (40°F to 300°F)
Maximum continuous exposure temperature
Intermittent on/off 250°C (482°F)
TubeTrace with VSX-HT

Request a quote

TubeTrace with VSX-HT

ring_volume +31 (0)183-201088 mail sales@tc-e.nl