Application
Thermon TubeTrace HTX2 is a preengineered electric traced tubing bundle for steam sample lines and impulse lines to pressure transmitters. TubeTrace HTX2 will provide freeze protection by maintaining pipe temperatures of 5°C (40°F) of steam lines in ambient conditions down to -34°C (-30°F) with 40 kph (25 mph) wind conditions. These high temperature bundles are designed to withstand continuous 399°C (750°F) superheat steam temperatures and/or intermittent temperatures of 593°C (1100°F) for a duration of 2 minutes per cycle even when power is applied to the heat trace during ambient conditions of 5°C (40°F).
In the past, the only option for tubing subject to high temperature exposure was heat traced with series resistance mineral insulated (MIQ) heat trace. MIQ heaters are custom made to fit each application, so long lead times and specific field measurments are often required. TubeTrace HTX2 solves this with Thermon parallel resistance HPT heat trace isolated from direct contact with high temperature tubing.
Thermon TubeTrace HTX2 bundles are approved for use in ordinary (nonclassified) areas and hazardous (classified) areas.
Features
- “Touch safe” jackets protect personnel
- “Cut-to-length” for faster installation
- Rated for intermittent exposure temperatures of 593°C (1100°F) for 2 minutes/2.5 hr cycle
- Designed for ambient sensing control at 5°C (+40°F)
- Freeze protect in ambient temperatures of -34°C (-30°F)
- HPT cable is approved for use in ordinary (non-classified) areas and hazardous (classified) areas
- Polymer outer jacket (ATP or TPU available)
Resources
Datasheet
English (Europe) datasheet
English (Americas) datasheet
Sales brochure
English (Americas) sales brochure
Product reference legend
English (Europe) reference legend
English (Americas) reference legend
Installation manual
English (Americas) installation instructions
Certifications/Approvals
FM Approvals
Ordinary Locations
Hazardous (Classified) Locations
Class I, Division 2, Groups B, C and D
Class II, Division 2, Groups F and G*
Class III, Divisions 1 and 2
Division 1 Locations requires Heater Cable Option 8:
Class I, Division 1, Groups B, C and D
Class II, Division 1, Groups E, F and G
Underwriters Laboratories Inc.
Ordinary Locations
Hazardous (Classified) Locations
Class I, Division 2, Groups B, C and D
Class II, Division 2, Groups E, F and G*
Class III, Divisions 1 and 2
Class I, Zone 1, AExe ll
Class I, Zone 2, AExe ll
Division 1 Locations requires Heater Cable Option 8:
Class I, Division 1, Groups B, C and D
Class II, Division 1, Groups E, F and G
Canadian Standards Association
Ordinary Locations
Hazardous (Classified) Locations
Class I, Division 2, Groups A, B, C and D
Class II, Division 2, Groups E, F and G
Class I, Division 1, Groups A, B, C and D
Class II, Division 1, Groups E, F and G
Ex e II
* CL. II, Div. 2 requires Thermon design review
Specifications
General
- Manufacturer
- Thermon
- Unit of measurement
- Meter
Ratings
- Available watt densities (°C) 230 Vac
- 15 W/m @ 10°C
- Supply voltages
- 120 to 240 Vac
- Maintain temperature
- 5°C (40°F) freeze protection
- Minimum design ambient
- -34°C (-30°F)
- Maximum continuous exposure temperature
- 399°C (750°F)
- Intermittent service temperature
- 593°C (1100°F)
- Minimum bend radius
- SEI-HTX2: 305 mm (12") / MEI-HTX2: 406 mm (16")